Image of TAMS Elektronik 40-19437-01 Booster B-4 mit Display Booster link DCC mfx MM
 

TAMS Elektronik 40-19437-01 Booster B-4 mit Display Booster link DCC mfx MM

DCC-conforming booster interface (3-pin / CDE) for connection to the DCC-conforming booster interface of a central unit or the track output of a central unit. Regulated Multi-protocol booster for use with MM, DCC or Central-mfx. For systems with feedback about Railcom and with symmetrical track voltage. Adjustable short conclusion sensitivity and rail voltage (10-20 V in 1 V steps). The RailCom Cutout of the boosters can be switched on/off. Internal short-circuit can also be switched off. Max. Track voltage 18 V; 5 A (controlled), setting to 12 to 24 V (regulated) is possible. 12 -18 V supply voltage (depending) on the set track voltage.Electrical properties: Power supply: AC transformer (12–20 V) or DC power supply (12–26 V)Maximum output current: 2.0 to 5.0 A, adjustable in 1 A stepsOutput voltage 10 to 24 volts Digital voltage (regulated), adjustable in 1 V stepsOutput signal: SymmetricLED on the front of the booster to indicate the operating states or problems that have occurred: Ready statusShort-circuit at the track outputBooster via a switch command switched offBooster switched off after triggering of the watchdog Booster switched off after exceeding the maximum permissible temperatureMissing signal from the central unitStart programmingDisplay:During operation: Current power consumption in the booster circuit [A] After a short circuit: The remaining seconds until the power is switched back on During programming: Display of set CV valuesSafety devices: Short-circuit shutdown: Internal short-circuit shutdown or short-circuit feedback to the digital control unit via CDE booster interface; automatic restart after a short-circuit; short-circuit warning to the PC controlSwitches off when overheatingWatchdog function in PC-controlled systemsConfiguration via main track programming (POM) or (with small restrictions) by setting short-circuit plugs (jumpers):Track voltage 10 – 24 V, adjustable in 1 V stepsRestart according to a short circuit: 4 – 10 sec., can be set in 1 sec. stepsMax. Track current (switch-off current in case of short circuit): 2 – 5 A, adjustable in 1 A-stepsRailCom: Active or inactiveSwitch-off with DCC switch-over command: Active or inactive Watchdog: Active or inactive Limit value for short circuit warning: 0.2 - 1 A, adjustable in 0.2 A stepsRestart time after 5 short circuits: 0 – 100 sec.This text is machine translated.

Price: EUR 154.99

Sitemap        Listing